Four quick questions, then pick the kit that matches your floor. DFT cable for odd-shaped rooms, DMC cable if you are using an uncoupling membrane, Elite mats when the room is mostly a rectangle. Give us a call if you want a second set of eyes on the square footage.

Voltage120 or 240Match the circuit. For DMC, the catalog notes 240 V is generally more economical over 70 sq ft.
What’s under the floorSpacingHeated room below = standard. Slab or crawl space = tighter spacing.
Room shapeCable or matIns and outs favor cable. Simple rectangles favor Elite mats.
1

A few questions first

Answer these before you open a chart

  1. 120 V or 240 V? Warm Tiles® runs on either. Decide before you order — the kit voltage has to match the circuit.
  2. What’s under the floor? A room over another heated space uses standard spacing. Concrete slabs, rooms over unheated areas, and high-loss spaces (the catalog names solariums) use tighter spacing.
  3. Simple rectangle, or lots of ins and outs? DFT and DMC cable follow the walkable floor around fixtures. Elite stock mats are rectangles. Irregular rooms use a factory custom WTE mat.
  4. Do you want a schedule? FGS, ES, and ESW can run a schedule. FG is a simple on/off temperature control.
2

Pick the product family

All three use a Warm Tiles® thermostat and the same floor sensor idea

DFT cable kitsCable on plastic strapping. Custom layouts. Standard 3" spacing or alternating 3" / 2". 10 ft cold lead. Catalog output: at least 12–15 W/ft² when installed per instructions.
DMC cable kitsPress into an uncoupling membrane or DMCS strips. Standard 12 W/ft², alternate 15 W/ft², dense 18 W/ft². Adds about 0.387" with membrane. 10 ft cold lead.
Elite (WTE) matsThin fabric mats (0.125" mat). Up to 15 W/ft² (14 W/ft² on select models). Adds about 0.211". 15 ft cold lead. Do not alter the heating cable. Custom shapes are made at the factory.
3

Measure only the walkable floor

Skip cabinets, the toilet flange, and a small border at the walls

Heated area is the walkable floor only — not cabinets, the toilet, or other fixtures. The catalog allows a border of 1½" to 6" from walls so the selected kit can fit. Keep heating cable at least 1½" from other cable, walls, vanity kick plates, and fixtures. Split the room into easy rectangles (and a triangle if you need one), then add them up.

Warm Tiles DFT room measurement diagram. Walkable areas A, B, and C in a 10 ft by 7 ft 6 in bathroom. Catalog example: A 7.5 + B 2.5 + C 15 = 25 sq ft heated.
Same 25 sq ft room. Standard DFT spacing → DFT 1022 (120 V). Alternating spacing → DFT 1030. Elite: a stock or custom mat near 25 sq ft, or two smaller mats.
4

DFT cable kits

Lace the cable. Snap it into the strapping in the kit.

Cable follows the walkable floor and stops at the vanity, toilet, and tub. Factory cold lead goes to the thermostat box.

Warm Tiles DFT cable layout in a bathroom, cable laced across walkable floor only. Typical DFT layout from the Warm Tiles catalog. 25 sq ft heated → DFT 1022 standard or DFT 1030 alternating (120 V).

Standard spacing is 3" (3 hubs on the strapping) for floors over a heated area. Alternating spacing is 3" / 2" / 3" / 2" for concrete slabs, rooms over unheated areas, and high heat loss. Use the same spacing over the whole floor. Installed per instructions, DFT is designed to supply at least 12–15 W/ft².

DFT standard 3 inch spacing versus alternating 3 inch and 2 inch spacing on plastic strapping. Left: standard 3". Right: alternating 3" / 2".

Pick 120 V or 240 V to match the circuit. Charts below are from the Warm Tiles catalog.

120 V DFT

ModelStandard sq ftAlternating sq ftAmps
DFT 101110–138–101.1
DFT 101614–1811–141.6
DFT 102219–2615–222.2
DFT 103027–3423–283.0
DFT 103935–4229–354.0
DFT 104843–5436–455.1
DFT 105955–6546–546.4
DFT 106966–7255–607.4
DFT 107973–8261–688.5
DFT 108883–9269–768.8
DFT 109893–10277–849.6
DFT 1108103–11385–9510.7

240 V DFT

ModelStandard sq ftAlternating sq ftAmps
DFT 202118–2515–211.1
DFT 203126–3522–291.6
DFT 205348–5540–462.6
DFT 206560–7050–583.3
DFT 207871–8359–704.0
DFT 209590–10075–845.1
DFT 2118110–13091–1086.3
DFT 2137131–145109–1207.4
DFT 2157146–165121–1378.5
DFT 2175166–184138–1538.8
DFT 2195185–204154–1699.6
DFT 2215205–225170–18710.7

Choose the kit whose range covers your heated square footage. Do not cut the heating cable to "make it fit.” Only the black cold lead may be shortened at the box.

5

DMC cable kits

For uncoupling membrane. Press the cable into the channels.

Measure the walkable floor the same way. Then press the cable into the membrane (or DMCS strapping) at one consistent spacing.

DMC walkable-area diagram for the same 10 ft by 7 ft 6 in bathroom. Same bath, walkable area only. Count channels, not floor inches.

Do not let the cable touch, cross, or overlap itself. On a membrane with 1.25" hub spacing: standard = 3 channels (3¾", 12 W/ft²); alternate = 3 then 2 channels (3¾" and 2½", 15 W/ft²); dense = 2 channels (2½", 18 W/ft²).

DMC cable in uncoupling membrane: standard, alternating, and dense spacing. In the membrane: standard · alternate · dense.
DMC cable on DMCS strapping strips at three hub spacings. Same three spacings on DMCS strapping if you are not using a membrane.
Standard3 channels apart~3¾" · about 12 W/ft² · typical heated room below
Alternate3 then 2 channels3¾" and 2½" · 15 W/ft² · catalog use: extra cable or a shortage
Dense2 channels apart~2½" · about 18 W/ft² · slab, crawl space, high loss

120 V DMC

ModelStandard sq ftAlternate sq ftDense sq ftAmps
DMC 101213–1511–128–101.3
DMC 101616–2013–1711–141.7
DMC 102122–2518–2115–172.3
DMC 102525–3021–2517–202.6
DMC 103131–3726–3121–253.3
DMC 104239–5233–4326–344.4
DMC 105353–6344–5235–425.5
DMC 106563–7752–6442–516.7
DMC 108180–9466–7853–638.3
DMC 109796–11280–9464–7510.0
DMC 1114111–13492–11274–9011.8

240 V DMC

ModelStandard sq ftAlternate sq ftDense sq ftAmps
DMC 202122–2518–2114–171.1
DMC 202525–3021–2517–201.3
DMC 203131–3726–3121–251.6
DMC 204239–5233–4326–342.2
DMC 205454–6445–5336–432.8
DMC 206362–7552–6241–503.3
DMC 208179–9765–8052–644.2
DMC 209794–11478–9563–765.0
DMC 2113112–13094–10975–875.8
DMC 2131130–150108–12587–1006.7
DMC 2163157–190131–158104–1278.3
DMC 2196190–227158–189127–15110.0
DMC 2231225–265187–221150–17711.8

If you are on the line between two kits, give us a call and we will pick with you.

6

Elite (WTE) mat kits

⅛" fabric. About 15 W/ft². Built for rectangles.

Stock mats are rectangles. Custom mats (bevel, hole, notch, L) are made at the factory for rooms with fixtures in the way. Do not alter the length of the heating cable inside the mat. Only the cold lead may be shortened at the electrical box.

Elite WTE standard rectangular mats versus a custom mat that follows the room. Left: standard rectangles. Right: custom coverage around fixtures.
Custom Elite mat shapes: bevel, hole, notch, and L-shape. Factory custom shapes: bevel, hole, notch, L.

Measure the walkable rectangle (or a few rectangles). Pick a mat — or two — whose listed heated area is at or just under that number. When using more than one mat, keep the outside wires of adjacent mats 1½" to 3" apart.

Part numbers read as WTE + length + width + voltage. Example: WTE0400481 is 40" × 48", 120 V, 13.3 sq ft. Change the last digit to 2 for the same size in 240 V.

Standard 120 V sizes from the catalog

ModelLength × width (in)Heated area sq ft
WTE040027140 × 277.5
WTE040032140 × 328.9
WTE040040140 × 4011.1
WTE040048140 × 4813.3
WTE048024148 × 248.0
WTE060024160 × 2410.0
WTE072036172 × 3618.0
WTE096048196 × 4832.0
WTE1180241118 × 2419.7
WTE1180301118 × 3024.6
WTE1180361118 × 3629.5
WTE1180421118 × 4234.4
WTE1180481118 × 4839.3
WTE1180601118 × 6049.2

Stock lengths run 40" to 118". Stock widths run 24" to 60" (not every length/width pair is offered). The catalog lists the matching 240 V models with a 2 at the end and the same square footage. Factory custom mats (bevel, hole, notch, L) are ordered when a stock rectangle leaves too much floor cold. Multiple mats can share one thermostat if the total load stays at or under 15 A.

7

Thermostat and power

Every kit needs a Warm Tiles® control and a GFCI-protected circuit

Use a current Warm Tiles® control from the catalog. All four stats below are dual-voltage, 15 A, with built-in GFCI.

ModelWhat it isLoad
FGNon-programmable floor-sensing thermostat120/240 V, 15 A
FGSProgrammable floor-sensing thermostat (5/2 or 7-day)120/240 V, 15 A
ESColorTouch thermostat — floor, air, or both115/230 V, 15 A
ESWWi-Fi ColorTouch — same as ES, plus app / browser control120/240 V, 15 A
RK1Relay kit when the load is over 15 A120 V, 24 A
RK2Relay kit when the load is over 15 A240 V, 24 A
  • Match kit voltage to the circuit. These stats accept both 120 V and 240 V.
  • Stay at or under 15 A on the thermostat. Above that, add RK1 (120 V) or RK2 (240 V) and a second feed.
  • DFT kit combinations over 10 A should be connected by a qualified electrician (catalog note).
  • These thermostats include a built-in GFCI. In a bathroom, the National Electrical Code still requires the circuit to be GFCI protected — confirm the requirement with your electrician or inspector.
  • A Detecto DT1 fault indicator monitors the cable during installation. It is not used to locate a fault after the floor is finished.
Need a hand? Send a simple sketch with the walkable areas labeled. We will point you at a kit and one of the stats above. Large multi-kit or multi-zone jobs are worth a quick call before you order.

Step 3:
  Thermostat Kit Selection Basics

How do I know which Warm Tiles® Thermostat Kit to buy?

Once you've chosen the Cable Kit(s) or Mat Kit(s) to cover your space, you'll need to add a Thermostat Kit for temperature control. Refer to the Chart below. Simply choose between a programmable or non-programmable model that matches your power supply and Cable Kit(s) or Mat Kit(s) voltage. The Warm Tiles® Thermostat Kit is designed for easy installation by a skilled do-it-yourselfer. However, you should always consult your local electrical inspection agency prior to beginning your installation. Refer to the Thermostat Installation and Operation Instructions in every Kit. Instructions vary between programmable and non-programmable models.

Product Selection Chart for Thermostat Kits

Warm Tiles® Thermostat Kits
Model No.Voltage
Programmable/
Non-Programmable
Maximum
Amperage
FGS120/240 Dual Voltage
Programmable15 Amps
FG120/240 Dual VoltageNon-Programmable15 Amps

Other Manufacturers Thermostat Choices

Honeywell/Aube Thermostat Kits
Model No.VoltageProgrammable/
Non-Programmable
Maximum
Amperage
TH114-AF-120GA120 Volts
Non-Programmable
15 Amps
TH114-AF-240GA240 Volts
Non-Programmable15 Amps
TH115-AF-GADual
Voltage
Programmable15 Amps

Step 4:  Large Floor Warming Installations

For larger spaces, more than one Warm Tiles® Cable or Mat Kit can be attached to a single thermostat as long as the total combined amperage of the kits do not exceed 15 Amps. If the heated area requires more than 15 Amps of load, you can choose to separate the area into more than one zone, each with its own thermostat contol, or install a
Relay Kit. 

What are Relay Kits?

Relay Kits are 24 Amp switches that are controlled by a single thermostat.  Like a thermostat, each relay can have two cable or mat kits attached to it, but can handle up to 24 Amps of load instead of the 15 Amp load maximum on a thermostat.  When combined with the 15 Amp capacity of a thermostat, up to 39 Amps of floor heating load can be controlled by a themostat/relay combination.  If this still doesn't cover the area you want controlled by a single thermostat, add another relay for an additional 24 Amps of load capacity.  With a thermostat/relay/relay combination, up to 63 Amps of load can be controlled by a single thermostat.  Keep in mind however that, like thermostats, relays require an electrical circuit (usually 30 Amps each) to operate, and must be connected to a thermostat and each other as per the instructions included with each Relay Kit.  This requires the ability to install the appropriate electrical conduit during the rough-in process, or having access during a renovation.  As a final note,
relays are typically housed in a separate electrical box at outlet height, and can be placed near the thermostat, or in any part of the room for ease of connection.

We hope this information was helpful. For additional information, refer to the other sections of this website (Literature, Video Training, Tutorials, FAQ's, Troubleshooting), or contact us directly with your questions.